Installation Instructions
21
The cooker can be close fitted below hotplate level. This requires
a minimum distance of 503mm between cupboard units of
hotplate height.
When installing next to a tall cupboard, partition or wall, for a
minimum distance of 400mm above hotplate level, allow a side
clearance of at least 65mm.
The diagram below illustrates the minimum clearance between
the cooker and adjacent walls, cupboards etc.
The wall behind the cooker 150mm below the hotplate and
450mm above, and the width of the cooker, must be a non-
combustible material such as ceramic wall tiles.
If the cooker is to be fitted close to a corner on the left hand side,
ensure that there is a clearance of at least 50mm to allow the main
oven door to open fully for when removing oven shelves.
If a cooker hood is to be installed, refer to the cooker hood manu-
facturers’ instructions regarding fixing height.